Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 8279, 2024 04 09.
Artículo en Inglés | MEDLINE | ID: mdl-38594403

RESUMEN

The aim of the study was to compare the anterior segment parameters after cataract surgery in pseudoexfoliation syndrome (PEX) and control eyes. We conducted a prospective comparative study of 36 eyes (PEX group), 16 eyes (PEXG group) and 46 eyes (control group) of 98 patients after phacoemulsification with intraocular lens implantation. Before surgery, 1 week, 1 month and 3 months postoperatively, anterior chamber parameters were evaluated by swept source anterior segment optical coherence tomography (AS-OCT). Anterior chamber depth (ACD), angle opening distance (AOD500/750), trabecular-iris space area (TISA500/750), trabecular-iris angle (TIA500/750) and lens vault (LV) were assessed at each study visit. Preoperatively, ACD, AOD500/750 and TISA500/750 were significantly smaller, while LV was significantly greater in PEX and PEXG eyes than in controls. 3 months postoperatively all irido-corneal parameters and ACD were significantly greater in all study groups without intergroup differences. ACD and LV significantly increased in PEX group between 1 and 3 months after surgery while being stable in control group. Relative increases in ACD, AOD500, TISA750, TIA500/750 were significantly higher in PEX and PEXG groups than in controls. Our study finds that ACD and iridocorneal parameters in AS-OCT demonstrated significantly greater relative increases 3 months after phacoemulsification in PEX and PEXG groups than in control eyes. Significantly greater deepening of anterior chamber and opening of the irido-corneal angle may be a reason for different refractive outcomes and IOP control in patients with PEX and PEXG after routine cataract surgery.


Asunto(s)
Catarata , Síndrome de Exfoliación , Humanos , Tomografía de Coherencia Óptica/métodos , Síndrome de Exfoliación/diagnóstico por imagen , Estudios Prospectivos , Presión Intraocular , Cámara Anterior , Segmento Anterior del Ojo/diagnóstico por imagen
2.
Sci Rep ; 11(1): 19071, 2021 09 24.
Artículo en Inglés | MEDLINE | ID: mdl-34561548

RESUMEN

To compare refractive outcomes after cataract surgery in pseudoexfoliation syndrome (PEX) and control eyes and to investigate the accuracy of 3 intraocular lens (IOL) calculation formulas in these eyes. In this prospective comparative study 42 eyes (PEX group) and 38 eyes (control group) of 80 patients were included. The follow-up was 3 months. The refractive prediction error (RPE), mean absolute error (MAE), median absolute error (MedAE) and the percentages of eyes within ± 0.25 D, ± 0.5 D, ± 1.0 D and ± 2.0 D of prediction error were calculated. Three IOL calculation formulas (SRK/T, Barrett Universal II and Hill-RBF) were evaluated. PEX produced statistically significantly higher mean absolute errors and lower percentages of eyes within ± 0.5 D than control eyes in all investigated IOL calculation formulas. There were no statistically significant differences in the median absolute errors between the 3 formulas in either PEX or control eyes. Refractive outcomes after cataract surgery are statistically significantly worse in PEX than in control eyes. All three IOL calculation formulas produced similar results in both PEX and control eyes.Trial registration: ClinicalTrials.gov registration number NCT04783909.


Asunto(s)
Síndrome de Exfoliación/cirugía , Implantación de Lentes Intraoculares , Lentes Intraoculares , Estudios de Casos y Controles , Extracción de Catarata/métodos , Síndrome de Exfoliación/fisiopatología , Humanos , Estudios Prospectivos , Agudeza Visual
3.
Clin Ophthalmol ; 14: 1373-1381, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32546945

RESUMEN

PURPOSE: The aim of this study was to describe clinical characteristics of glaucomatous optic neuropathy in treated Polish patients with pseudoexfoliative glaucoma. METHODS: In the course of the study, 348 eyes of 231 patients with pseudoexfoliative glaucoma. The patients involved in the study were treated in the Department of Diagnostic and Microsurgery of Glaucoma in Lublin between 2012 and 2019. The following parameters were assessed in the examination: visual acuity, slit-lamp biomicroscopy with evaluation of anterior segment of the eye, gonioscopic examination, stereoscopic fundus examination of the eye, intraocular pressure, visual field, and pachymetry. RESULTS: The mean age of all the patients was 73.16 years (SD±8.03). The mean age of women was 74.06 (SD±6.97), and the mean age of men was 71.8 (SD±8.51, p=0.006265). Women represented 37.93% (n=132) of the studied group, while men 62.07% (n=216). In the group of patients younger than 65 years of age, 27.9% were male and 15% female (p=0.0021). In the whole studied group, mean peak IOP was 29.25 mmHg with higher mean values in male patients (M vs F: 33.24 mmHg vs 26.86 mmHg; p=0.000). Peak values exceeding 30 mmHg were significantly more frequent in males (M vs F: 56.5% vs 31.9%; p=0.0000). Peak IOP never exceeding 21 mmHg was observed in 18.6% of the patients. The mean value of MD (Mean Deviation) was -12.85 dB in the whole group. The men were more likely to have more advanced glaucoma, according to MD (M vs F: -16.35 dB vs -11.13 dB; p=0.0000). CONCLUSION: Pseudoexfoliative glaucoma was more frequently observed in men with younger age, higher IOP, and more advanced glaucoma. Normotensive glaucoma was observed in 18.6% of the patients with pseudoexfoliative glaucoma.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...